The RG300 series fuel cell test platform is designed for high-power fuel cell stacks, suitable for performance evaluation of hydrogen-air/hydrogen-oxygen fuel cells with a rated power range of 30kW to 500kW. This testing platform features high measurement accuracy and high stability, with precise and controllable operating conditions; it is equipped with safety-assured hardware and multiple software safety designs, enhancing the platform's reliability and safety; at the same time, the platform is designed with a powerful human-machine interface, offering a variety of operation modes and control methods for users to choose from, enabling continuous unmanned automatic operation for several days; the operating status and parameters of the fuel cell can be adjusted and monitored online, and all monitoring data can be stored in real time.
Model | RG310 | RG315 | RG320 | RG330 | RG350 |
Rated Power | 100kW | 150kW | 200kW | 300kW | 400kW |
Anode Gas Flow Control Range | 2500SLPM | 3000SLPM | 4000SLPM | 6000SLPM | 8000SLPM |
Cathode Gas Flow Control Range | 6000SLPM= | 10000SLPM | 14000SLPM | 18000SLPM | 25000SLPM |
Control Accuracy | ±(0.8%RD+0.2%F.S.) | ||||
Humidity Method | Bubbling/Spraying | ||||
DewPoint Temperature Control Range | Environment temperature: +10°C to 90°C | ||||
Temperature Control Accuracy | ±1°(steady state) ±2°(Dynamic) | ||||
Heating Rate | 1~5°C/min | ||||
Back Pressure | 0.02 ~3 bar | ||||
Back pressure control accuracy. | ≤±2kpa(稳态) | ||||
Single Voltage Detection Function | Channels: 40 (expandable); Single voltage measurement range: ±4V; Accuracy: 1mV; | ||||
Electronic Load (Current and voltage can be adjusted as needed) | 800V、120A | 800V、12000A | 800V、1200A | 1000V、1200A | 1000V、1200A |